IMAGE

FIG 4

ID
ZDB-IMAGE-201003-227
Source
Figures for Yakimovich et al., 2020
Image
Figure Caption

FIG 4

Mimicry embedding can be used for weak-labeling particle classification. (A) Merged four channel fluorescent image of a HeLa cell infected with VACV previously unseen by CapsNet (see Fig. S4A for channel details). (B) ZedMate detection and trained-CapsNet-predicted extracellular and intracellular particles. (Inset) Quantification of intracellular particles. (C) Merged four-channel image of HeLa cell infected with VACV and treated with the entry inhibitor IPA-3, previously unseen by CapsNet. (D) ZedMate detection and trained CapsNet inference of intracellular and extracellular particles. (Inset) Quantification of intracellular particles. (E) Representative reconstruction profiles of extra- and intracellular virions. (F) Representative mimicry-embedded extra- and intracellular VACV particles for comparison to the images in panel E. n = 40 (3 biological replicates) untreated and treated cells each. Detailed model performance (statistical validation) metrics are provided in Fig. S4. Bars, 10 μm.

Acknowledgments
This image is the copyrighted work of the attributed author or publisher, and ZFIN has permission only to display this image to its users. Additional permissions should be obtained from the applicable author or publisher of the image. Full text @ mSphere